VVM111 - 400V DC Isolated Voltage Sensor Module with Serial UART Communication MODBUS Compatible
Product Description
The VVM111 provides isolated DC voltage measurement from 0 to 400 V for industrial and commercial monitoring systems. It offers 1.5 kV DC galvanic isolation between the measured voltage and communication lines, and operates from a separate 9–24 V DC supply.
Measured voltage is available digitally through a TTL UART serial interface at three readings per second. The default baud rate is 9600, with a programmable 19200 option. Modbus RTU slave operation is supported using an external TTL-to-RS485 converter, with programmable slave addresses from 1 to 247.
Product Specifications
| Model | VVM111 |
| Datasheet version | v1.2 |
| Measurement | 0–400 V DC |
| Galvanic isolation | 1.5 kV DC between measured voltage and communication lines |
| Operating supply | 9–24 V DC |
| Interface | TTL UART |
| Baud rates | 9600 default; 19200 selectable |
| Data update rate | 3 readings per second |
| Serial format | V350.89D followed by newline (example: 350.89 V DC) |
| Modbus operation | RTU slave through external TTL-to-RS485 converter |
| Slave ID | 1–247; default 1 |
| Voltage registers | 40001–40002; 32-bit float |
| Modbus example settings | Function 03; two registers; high byte first; high word first |
| Baud command | BAU1: 9600; BAU2: 19200 |
| Mode commands | MOD: Modbus slave; SERIALON: serial mode |
| Slave ID command | SLVXXX, e.g. SLV005 |
| Calibration command | CALXXX.XX, e.g. CAL054.60 |
| Board dimensions | 80 × 36 mm |
Product Features
- 0–400 V DC isolated voltage measurement
- 1.5 kV DC isolation between measured voltage and communication lines
- 9–24 V DC operating supply
- TTL UART serial output; 3 readings per second
- Selectable 9600 or 19200 baud; 9600 default
- Modbus RTU slave with external TTL-to-RS485 converter
- Programmable slave ID 1–247; default 1
- Serial calibration with stored calibration factor
- Compact 80 × 36 mm PCB
- Follow the manufacturer's serial commands to configure baud rate, slave ID, operating mode and calibration.
Package Includes
- 1 × VVM111 isolated DC voltage sensor module
- Power supply and TTL/USB/RS485 interface converters are not specified as included.
Frequently Asked Questions
What voltage range does VVM111 measure?
How do I read voltage through UART?
Does it connect directly to an RS485 network?
Which Modbus registers contain voltage?
Can baud rate, operating mode and calibration be changed?
Other Information
Warranty Information
1 Year Seller Warranty
This item is covered with a standard warranty of 1 year from the time of delivery against manufacturing defects only. This warranty is given for the benefit of TwoElectrons customers from any kind of manufacturing defects. Replacement will be done against manufacturing defects.
What Voids Warranty
If the product is subject to misuse, tampering, static discharge, accident, water or fire damage, use of chemicals & soldered or altered in any way.
Shipping & Returns Policy
Shipping Policy:
- In-stock items are delivered within 7-10 working days for orders within India. Delivery varies based on location and courier service.
- In-stock items are delivered within up to 20 working days for orders outside India. Delivery varies based on location and courier service.
- If the item is out of stock, you can still place an order. The estimated delivery time will be notified to you by email.
Return & Refund Policy:
- Return window: 7 days from receipt unless stated otherwise.
- No refunds or replacements after the return window.
- Returns are accepted only for non-working or damaged products.
- Initiate return requests from here: Return Request or contact us at 09831070550.
- Refunds are processed within 3-4 working days after inspection and approval.
Main Features
- 0–400 V DC isolated voltage measurement
- 1.5 kV DC isolation between measured voltage and communication lines
- 9–24 V DC operating supply
- TTL UART serial output; 3 readings per second
- Selectable 9600 or 19200 baud; 9600 default
- Modbus RTU slave with external TTL-to-RS485 converter
- Programmable slave ID 1–247; default 1
- Serial calibration with stored calibration factor
- Compact 80 × 36 mm PCB
Lead time
| QUANTITY | DISPATCH |
|---|---|
| 1-10 units |
Order from India: 7-10 working days Order outside India: Up to 20 working days |
| 10+ units | To be negotiated |
Protections for this product
Delivery via TwoElectrons Logistics
We aim to deliver your order within the scheduled dates, but delays may occur due to unforeseen circumstances.
Secure Payments
Your payment information is safe with us. TwoElectrons.com uses SSL encryption to ensure secure and reliable transactions.
Standard Refund Policy
You're covered! If your order doesn't ship, arrives incomplete, or has any product issues, you can claim a full refund.