VVM302 - Digital DC Voltage Current Energy Sensor Module 100V 100A with Watt hour, Ampere hour, Serial UART Communication, Over-Current Detection, MODBUS Compatible

Low Stock, 1 left
VVM302 100V 100A DC voltage current and energy sensor module

Product Description

The VVM302 is a digital DC voltage, current and energy sensor module for industrial and commercial monitoring. It measures DC voltage up to 100 V and bidirectional DC current up to ±100 A using a WCS1600 Hall effect sensor with a 9.0 mm conductor aperture. Current measurement requires no shunt resistor or break in the measured conductor.

The module measures watt-hours and ampere-hours for energy and battery-capacity monitoring. Analog voltage outputs and UART serial communication support microcontrollers and data acquisition systems. Modbus RTU slave operation requires an external TTL-to-RS485 converter. A 16 × 2 LCD can optionally connect to the 16-pin header. An adjustable over-current threshold, active-low alarm output and calibration modes support system integration.

Product Specifications

ModelVVM302
Versionv1.3
MeasurementDC voltage, current, power, watt-hour and ampere-hour / coulomb count
Voltage rangeUp to 100 V DC
Current range±100 A DC
Current sensingWCS1600 Hall effect
Auxiliary supply7–12 V DC maximum
DisplayOptional 16 × 2 LCD via 16-pin header; contrast potentiometer
Current output sensitivity22 mV/A
Voltage output sensitivity25 mV/V
Current calculationI (A) = (Iout − 2.5) / 0.022
Conductor aperture9.0 mm diameter
Board dimensions80 × 36 mm (datasheet drawing); mounting-hole spacing 75 × 35 mm
Current-measurement electrical isolation4000 V; voltage-input isolation is not specified
Sensor bandwidth>20 kHz; serial/display update rate not specified
Magnetic hysteresisNearly zero
CommunicationTTL UART Tx/Rx; external TTL-to-RS485 converter required for Modbus RTU
Baud rates9600 (default), 19200, 38400, 57600, 115200
Modbus slave ID1 default; programmable 1–247
Modbus registers40001–40002 voltage; 40003–40004 current; 40005–40006 Wh; 40007–40008 Ah; 32-bit float
Over-current outputO/C LOW on over-current, HIGH otherwise; LED indication
Threshold adjustmentRV1 potentiometer: clockwise increases, anticlockwise decreases
Operating modesVoltage/current; voltage/current/Wh/Ah; over-current setting; zero-current calibration
ConnectionsGND, NC, +12v, Iout, O/C, Tx, Rx, Vout, EN and two-pin VIN
Converter enableEN connects to DE and RE of external TTL-to-RS485 converter
Energy data retentionSend S + Enter to save Wh/Ah; R + Enter resets stored values

Product Features

  1. DC voltage measurement up to 100 V and bidirectional current measurement up to ±100 A
  2. WCS1600 Hall effect current sensing without a shunt resistor
  3. Optional 16 × 2 LCD support via a 16-pin header; UART output for voltage, current, Wh and Ah
  4. Analog current and voltage outputs: 22 mV/A and 25 mV/V
  5. UART serial interface; programmable baud rate from 9600 to 115200
  6. Modbus RTU slave operation via an external TTL-to-RS485 converter
  7. Adjustable over-current threshold with active-low digital output
  8. 9.0 mm conductor aperture; compact board for embedded integration
  9. 4000 V current-measurement isolation; sensor bandwidth >20 kHz
  10. Local push-button calibration and factory reset
  11. Serial commands to save or reset energy counters

Package Includes

  • 1 × VVM302 DC voltage, current and energy sensor module
  • LCD, enclosure, auxiliary power supply and TTL-to-RS485/USB converter are not specified as included.

Frequently Asked Questions

What voltage and current can the VVM302 measure?
It measures DC voltage up to 100 V and bidirectional DC current up to ±100 A. The WCS1600 Hall effect sensor measures current through a 9.0 mm aperture without a shunt resistor. Current sensing is less accurate at very low currents.
What power supply does the VVM302 require?
Use a stable 7–12 V DC auxiliary supply connected to +12v and GND. The 100 V measurement rating applies to VIN, not the auxiliary power input. Observe VIN polarity. The datasheet specifies 4000 V isolation for current measurement; it does not specify voltage-input isolation.
Does it support UART and Modbus RTU?
Yes. UART is available on Tx/Rx, with 9600 baud by default and selectable rates up to 115200. Modbus RTU slave operation requires an external TTL-to-RS485 converter, with EN connected to the converter's DE and RE pins. Slave IDs 1–247 are supported; the default is 1. Regular UART data output is unavailable while in Modbus mode.
Are watt-hour and ampere-hour readings retained after power-off?
Send S followed by Enter through the serial port to save Wh and Ah values in device memory before power-off. Send R followed by Enter to reset the stored readings to zero.
Does the VVM302 include a display, and how is over-current detected?
The module supports an optional 16 × 2 LCD connected to its 16-pin header; LCD contrast is adjusted with the LCD potentiometer. An LCD is not specified as included. Set the over-current threshold locally with RV1: clockwise increases it and anticlockwise decreases it. On over-current, O/C goes LOW and LED L2 illuminates.

Other Information

Applications: test and measurement, instrumentation and control, motor control, power and solar systems, battery chargers, state-of-charge estimation, electric vehicles, load detection and over-current fault detection.

Connect the auxiliary supply to +12v and GND. Observe correct VIN polarity and conductor direction. Analog Vout and Iout signals are outputs. Current measurement is electrically isolated; the datasheet does not specify isolated voltage measurement.

Baud rate and slave ID are configured over the serial port. Modbus mode requires a local button operation and an external TTL-to-RS485 converter; regular UART data output is unavailable while operating in Modbus mode. Remote Configuration Support means seller support availability.

Wh and Ah are retained after power-off when saved with S + Enter. Use R + Enter to reset stored readings. Hall effect sensing is less accurate at very low currents. If the serial port is unused, connect Rx and NC as instructed by the manufacturer. Use a stable, good-quality auxiliary supply.

Warranty Information

1 Year Seller Warranty

This item is covered with a standard warranty of 1 year from the time of delivery against manufacturing defects only. This warranty is given for the benefit of TwoElectrons customers from any kind of manufacturing defects. Replacement will be done against manufacturing defects.

What Voids Warranty

If the product is subject to misuse, tampering, static discharge, accident, water or fire damage, use of chemicals & soldered or altered in any way.

Shipping & Returns Policy

Shipping Policy:
  • In-stock items are delivered within 7-10 working days for orders within India. Delivery varies based on location and courier service.
  • In-stock items are delivered within up to 20 working days for orders outside India. Delivery varies based on location and courier service.
  • If the item is out of stock, you can still place an order. The estimated delivery time will be notified to you by email.
Return & Refund Policy:
  • Return window: 7 days from receipt unless stated otherwise.
  • No refunds or replacements after the return window.
  • Returns are accepted only for non-working or damaged products.
  • Initiate return requests from here: Return Request or contact us at 09831070550.
  • Refunds are processed within 3-4 working days after inspection and approval.

Main Features

  • DC voltage measurement up to 100 V and bidirectional current measurement up to ±100 A
  • WCS1600 Hall effect current sensing without a shunt resistor
  • Optional 16 × 2 LCD support via a 16-pin header; UART output for voltage, current, Wh and Ah
  • Analog current and voltage outputs: 22 mV/A and 25 mV/V
  • UART serial interface; programmable baud rate from 9600 to 115200
  • Modbus RTU slave operation via an external TTL-to-RS485 converter
  • Adjustable over-current threshold with active-low digital output
  • 9.0 mm conductor aperture; compact board for embedded integration
  • 4000 V current-measurement isolation; sensor bandwidth >20 kHz
SKU: 2EMK30012
₹ 1,683.00
For bulk orders, volume pricing & B2B enquiries, contact our team →

Lead time

QUANTITY DISPATCH
1-10 units Order from India: 7-10 working days
Order outside India: Up to 20 working days
10+ units To be negotiated
Icon
Need Support?
Click here
Icon
Free delivery above ₹5,000
Icon
1 year product warranty
Icon
Secure payment options
Protections for this product
Delivery
Delivery via TwoElectrons Logistics

We aim to deliver your order within the scheduled dates, but delays may occur due to unforeseen circumstances.

Security
Secure Payments

Your payment information is safe with us. TwoElectrons.com uses SSL encryption to ensure secure and reliable transactions.

Security
Standard Refund Policy

You're covered! If your order doesn't ship, arrives incomplete, or has any product issues, you can claim a full refund.