VVM311 - 400V 200A DC Isolated Voltage and Current Sensor Module with Serial UART Communication MODBUS Compatible
Product Description
The VVM311 provides isolated DC voltage measurement from 0 to 400 V and Hall effect DC current measurement up to 200 A using a WCS1500 sensor. The non-invasive current sensor requires no shunt resistor or wire break, making the module suitable for industrial monitoring and data acquisition.
It operates from a 9–24 V DC supply and provides measured voltage and current over a TTL UART interface at three readings per second. The datasheet specifies 1.5 kV DC isolation between the measured voltage and communication lines. Modbus RTU slave operation requires an external TTL-to-RS485 converter.
The 80 × 36 mm board supports programmable 9600/19200 baud rates, slave addresses 1–247, voltage and current calibration, and zero-current offset correction.
Product Specifications
| Model / version | VVM311 / v1.2 |
| Voltage range | 0–400 V DC |
| Current range | Up to 200 A DC |
| Current sensor | WCS1500 Hall effect |
| Isolation | 1.5 kV DC between measured voltage and communication lines |
| Operating supply | 9–24 V DC |
| PCB dimensions | 80 × 36 mm |
| Interface | TTL UART; external converters for RS232/RS485 integration |
| Data rate | 3 readings per second |
| Baud rates | 9600 default / 19200 |
| Serial format | V350.89DC32.64D followed by newline (example) |
| Modbus | RTU slave via external TTL-to-RS485 converter |
| Slave ID | 1–247; default 1 |
| Registers | 40001–40002 voltage; 40003–40004 current; 40005–40006 power; 32-bit floats |
| Baud commands | BAU1 / BAU2 |
| Mode commands | MOD / SERIALON |
| Address command | SLVXXX, e.g. SLV005 |
| Voltage calibration | CALXXX.XX, e.g. CAL054.60 |
| Current calibration | CLIXXX.XX, e.g. CLI025.00 |
| Zero correction | ZER with no current flowing |
Product Features
- 0–400 V DC voltage measurement
- Up to 200 A DC current measurement using WCS1500 Hall sensor
- Non-invasive current sensing; no shunt resistor or wire break
- 1.5 kV DC isolation between measured voltage and communication lines
- 9–24 V DC operating supply
- TTL UART output at three readings per second
- 9600 default baud; selectable 19200
- Modbus RTU slave through external TTL-to-RS485 converter
- Programmable slave ID 1–247; default 1
- Voltage, current and zero-current calibration commands
- 80 × 36 mm PCB
Package Includes
- 1 × VVM311 isolated voltage and current sensor module
- Auxiliary power supply and TTL-to-USB/RS485 converters are not specified as included.
Frequently Asked Questions
What ranges does VVM311 measure?
What supply and isolation are specified?
What UART data and baud rates are available?
How is Modbus RTU used?
How is calibration performed?
Other Information
Warranty Information
1 Year Seller Warranty
This item is covered with a standard warranty of 1 year from the time of delivery against manufacturing defects only. This warranty is given for the benefit of TwoElectrons customers from any kind of manufacturing defects. Replacement will be done against manufacturing defects.
What Voids Warranty
If the product is subject to misuse, tampering, static discharge, accident, water or fire damage, use of chemicals & soldered or altered in any way.
Shipping & Returns Policy
Shipping Policy:
- In-stock items are delivered within 7-10 working days for orders within India. Delivery varies based on location and courier service.
- In-stock items are delivered within up to 20 working days for orders outside India. Delivery varies based on location and courier service.
- If the item is out of stock, you can still place an order. The estimated delivery time will be notified to you by email.
Return & Refund Policy:
- Return window: 7 days from receipt unless stated otherwise.
- No refunds or replacements after the return window.
- Returns are accepted only for non-working or damaged products.
- Initiate return requests from here: Return Request or contact us at 09831070550.
- Refunds are processed within 3-4 working days after inspection and approval.
Main Features
- 0–400 V DC voltage measurement
- Up to 200 A DC current measurement using WCS1500 Hall sensor
- Non-invasive current sensing; no shunt resistor or wire break
- 1.5 kV DC isolation between measured voltage and communication lines
- 9–24 V DC operating supply
- TTL UART output at three readings per second
- 9600 default baud; selectable 19200
- Modbus RTU slave through external TTL-to-RS485 converter
- Programmable slave ID 1–247; default 1
- Voltage, current and zero-current calibration commands
- 80 × 36 mm PCB
Lead time
| QUANTITY | DISPATCH |
|---|---|
| 1-10 units |
Order from India: 7-10 working days Order outside India: Up to 20 working days |
| 10+ units | To be negotiated |
Protections for this product
Delivery via TwoElectrons Logistics
We aim to deliver your order within the scheduled dates, but delays may occur due to unforeseen circumstances.
Secure Payments
Your payment information is safe with us. TwoElectrons.com uses SSL encryption to ensure secure and reliable transactions.
Standard Refund Policy
You're covered! If your order doesn't ship, arrives incomplete, or has any product issues, you can claim a full refund.