VVM312 - 400V 100A DC Isolated Voltage and Current Sensor Module with Serial UART Communication MODBUS Compatible
Product Description
The VVM312 provides isolated DC voltage measurement from 0 to 400 V and Hall effect current measurement up to 100 A for industrial and commercial monitoring. Its WCS1600 sensor measures current without a shunt resistor or breaking the measured conductor.
The module provides 1.5 kV DC isolation between the measured voltage and communication lines. A TTL UART interface supplies voltage and current readings, with programmable baud rate and serial calibration commands. Modbus RTU slave operation is supported through an external TTL-to-RS485 converter. The compact 80 × 36 mm board operates from a 9–24 V DC auxiliary supply.
Product Specifications
| Model | VVM312 |
| Version | v1.2 |
| DC voltage range | 0–400 V |
| DC current range | Up to 100 A |
| Current sensor | WCS1600 Hall effect |
| Isolation | 1.5 kV DC between measured voltage and communication lines |
| Auxiliary power | 9–24 V DC |
| PCB dimensions | 80 × 36 mm |
| Interface | TTL UART; external converter required for RS232/RS485 integration |
| Baud rate | 9600 default; 19200 selectable |
| Serial update rate | 3 values per second |
| Serial format | V350.89DC32.64D followed by newline; V = voltage, C = current, D = DC delimiter |
| Module pin labels | 9–24v, supply negative, Rx, Tx, NC; VIN screw terminals |
| Module Rx pin | Measurement data output, per manufacturer pin labeling |
| Module Tx pin | Configuration command input, per manufacturer pin labeling |
| Slave ID | 1 default; 001–247 allowed |
| Modbus registers | 40001–40002 voltage; 40003–40004 current; 40005–40006 power; 32-bit float |
| Baud commands | BAU1 = 9600; BAU2 = 19200; reset as prompted |
| Mode commands | MOD enters Modbus; SERION returns to serial |
| Voltage calibration | CALXXX.XX; e.g. CAL054.60 |
| Current calibration | CLIXXX.XX; e.g. CLI025.00 |
| Zero-current calibration | ZER |
Product Features
- 0–400 V DC isolated voltage measurement
- DC current measurement up to 100 A using WCS1600 Hall effect sensing
- Non-invasive current sensing without a shunt resistor
- 1.5 kV DC isolation between measured voltage and communication lines
- 9–24 V DC auxiliary power supply
- TTL UART output; programmable 9600 or 19200 baud
- Modbus RTU slave via external TTL-to-RS485 converter
- Programmable slave ID 1–247; default 1
- 80 × 36 mm compact PCB
- Voltage and current calibration through serial commands
- Stored calibration factors and serial zero-current correction
Package Includes
- 1 × VVM312 isolated DC voltage and current sensor module
- Auxiliary supply and TTL-to-USB/RS485 converters are not specified as included.
Frequently Asked Questions
What voltage and current can the VVM312 measure?
What supply and isolation does it provide?
Does the module support Modbus RTU?
What serial settings and data are available?
How do I calibrate voltage and current readings?
Other Information
Warranty Information
1 Year Seller Warranty
This item is covered with a standard warranty of 1 year from the time of delivery against manufacturing defects only. This warranty is given for the benefit of TwoElectrons customers from any kind of manufacturing defects. Replacement will be done against manufacturing defects.
What Voids Warranty
If the product is subject to misuse, tampering, static discharge, accident, water or fire damage, use of chemicals & soldered or altered in any way.
Shipping & Returns Policy
Shipping Policy:
- In-stock items are delivered within 7-10 working days for orders within India. Delivery varies based on location and courier service.
- In-stock items are delivered within up to 20 working days for orders outside India. Delivery varies based on location and courier service.
- If the item is out of stock, you can still place an order. The estimated delivery time will be notified to you by email.
Return & Refund Policy:
- Return window: 7 days from receipt unless stated otherwise.
- No refunds or replacements after the return window.
- Returns are accepted only for non-working or damaged products.
- Initiate return requests from here: Return Request or contact us at 09831070550.
- Refunds are processed within 3-4 working days after inspection and approval.
Main Features
- 0–400 V DC isolated voltage measurement
- DC current measurement up to 100 A using WCS1600 Hall effect sensing
- Non-invasive current sensing without a shunt resistor
- 1.5 kV DC isolation between measured voltage and communication lines
- 9–24 V DC auxiliary power supply
- TTL UART output; programmable 9600 or 19200 baud
- Modbus RTU slave via external TTL-to-RS485 converter
- Programmable slave ID 1–247; default 1
- 80 × 36 mm compact PCB
Lead time
| QUANTITY | DISPATCH |
|---|---|
| 1-10 units |
Order from India: 7-10 working days Order outside India: Up to 20 working days |
| 10+ units | To be negotiated |
Protections for this product
Delivery via TwoElectrons Logistics
We aim to deliver your order within the scheduled dates, but delays may occur due to unforeseen circumstances.
Secure Payments
Your payment information is safe with us. TwoElectrons.com uses SSL encryption to ensure secure and reliable transactions.
Standard Refund Policy
You're covered! If your order doesn't ship, arrives incomplete, or has any product issues, you can claim a full refund.